J28 proportional hsm output configuration – MTS FlexTest Models 200 User Manual

Page 250

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 493.74 Two-Station HSM Interface Board

Digital I/O and Transition Boards

250

J28 Proportional HSM Output Configuration

The proportional HSM output option provides a current source that drives a
proportional solenoid on the HSM. The proportional output is configured
with the controller software.

Pressure settings

This board supports software-selectable HSM High and Low pressure
settings.

HSM rate settings

This board supports the following software-selectable HSM rate settings:
Fast (2 seconds) or Slow (4 seconds).

To calculate ramp rates

To calculate ramp times

The amount of time to reach low and high pressure depends on the Low and
High pressure settings and the HSM Rate setting.

Fast Rate (psi/s)

Maximum HSM Pressure (psi)

2 s (Fast)

-------------------------------------------------------------------------

=

Slow Rate (psi/s)

Maximum HSM Pressure (psi)

4 s (Slow)

-------------------------------------------------------------------------

=

Ramp time to low psi (s)

Low setting (psi)

Rate (psi/s)

-----------------------------------------

=

Ramp time to high psi (s)

High setting (psi)-Low setting (psi)

Rate (psi/s)

-------------------------------------------------------------------------------------

=