Cable specification, Jumper plug – MTS FlexTest Models 200 User Manual

Page 251

Advertising
background image

Model 493.74 Two-Station HSM Interface Board

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Digital I/O and Transition Boards

251

J29 Load Frame Connections for the Model 493.74 HSM Board

Connector J29 Load Frame connects to the load unit control module. Load
frame signals include E-Stop and crosshead controls for each station.

Cable specification

To maintain EMC compliance, J29 Load Frame cables must comply with
the following specifications:

Connector–15-contact, type D, male EMI connector with conductive
backshell.

Cable for load frames with crosshead locks built after 1985–18 AWG, 8
conductor with overall foil shield with drain wire connected to the
conductive backshell.

Cable for all load frames without crosshead locks–22 AWG, 6 conductor
with overall foil shield with drain wire connected to the conductive
backshell.

Jumper plug

If connector J29 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug part number 100-007-947 or
jumper pins: 3 and 4; 5 and 7; 11 and 15; 8 and 13.

Cross Head Unlock

493.74 HSM Board

J29A

J29B

Intlk

J28B HSM

R

J43-1

J43-2

Run/Stop

J44-1

J44-2

Aux Power

J49-1

J49-2

Load Frame

J29-1

J29-2

J28A HSM

493.74

HSM

Station

Emergency

Stop

Crosshead

Unlock

Input

DC Common

HSM Hi

Crosshead

Solenoid

+24 V

Station

Interlock

CRM

Relay

in HPU

J29

Load Frame

1

4

3

2

13

8

7

5

12

14

To Load Unit

Control Module

HSM High=Unlock Enabled

Open=Program

Interlock

Note: Pins 11 and 15 are reserved

+24 V DC

+24 V DC

OR Station

Stop

Advertising