Run/stop status output, Interlock status output, Cable specification – MTS FlexTest Models 200 User Manual

Page 254

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 493.74 Two-Station HSM Interface Board

Digital I/O and Transition Boards

254

J44 Run/Stop Connections for the Model 493.74 HSM Board

Run/Stop status

output

Connector J44 Run/Stop provides the run/stop status of the controller to
external devices.

Two form C contacts provide the run/stop status.

The contacts are rated 1.0 A at 30 V (AC or DC).

Interlock status output

Connector J44 Run/Stop also provides opto-isolator outputs that indicate
the interlock status of each station to an external device. These interlock
status outputs are normally on and will turn off when an interlock occurs.

Cable specification

To maintain EMC compliance, J44 Run/Stop cables must comply with the
following specifications:

Connector–9-contact, type D, female EMI connector.

Backshell–EMI metallized plastic or metal.

Cable–AWG and number of conductors as required. Braided shield with
shield connected to the metallized backshell at the chassis.

Run/Stop 2

+

-

Interlock Status

Output

493.74 HSM Board

J44-2

J44-1

Intlk

J28B HSM

R

J43-1

J43-2

Run/Stop

J44-1

J44-2

Aux Power

J49-1

J49-2

Load Frame

J29-1

J29-2

J28A HSM

493.74

HSM

Station

1

2

3

4

5

6

7

8

Run/Stop 1

J44

Run/Stop

To

External

Devices

Advertising