MTS FlexTest Models 200 User Manual

Page 260

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 493.80 Encoder Interface Board

Digital I/O and Transition Boards

260

Mode Settings for the Model 493.80 Encoder Interface Board

Each channel on the Model 493.80 board includes jumpers that you can
configure for various modes.

Note

When used with the Model 494.49 Quad Encoder board, the jumper
setting for each channel’s mode must be the same (all SSI or all
non-SSI).

Mode settings include:

SSI devices–such as Temposonics R transducers, Gurley and other
absolute encoders

Non-SSI devices–such as incremental encoders, and PWM devices
such as Temposonics G transducers.

493.80 Encoder Interface Board

Mode Settings

X19

Channel 1

= Non-SSI Device

Channel 2
Channel 3

Channel 4

= SSI Device

J3

J4

J5

J6

X3

X4

X5 X6

J11

J12

X7

X8

X9 X10

X1

1

X12

X13 X14

X15

X16

X17

X18

X19

Mode Settings for use with

Model 494.49 Quad Encoder Card

X19

= SSI Devices

= Non-SSI Devices

X19