Interlock input options – MTS FlexTest Models 200 User Manual

Page 264

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 494.74 Two-Station HSM Interface Board

Digital I/O and Transition Boards

264

J3 Interlock Connections for the Model 494.74 HSM Board

Each HSM channel has interlock inputs and outputs that are available
through connector J3A or J3B (one channel per connector). Interlock output
contacts can control external devices. Interlock inputs from external devices
can initiate station and program interlocks.

Interlock In (Ground)

Interlock Out (NO)
Interlock = Open

Interlock Out (NC)
Interlock = Closed

Common

Run/Stop (NC)
Stop = Closed

Run/Stop (NO)
Stop = Open

Common

- Interlock In

+ Program Intlk In

- Program Intlk In
Open = Program Interlock

+ Interlock In

Interlock In (Power)

+24V

J3 A/B

(D15S)

494.74 HSM Board

5

13

6

14

7

15

4

1

9

12

2

10

J49 AUX PWR

J3A STA

J3B STA

J28A HSM

J28B HSM

+24V

4

1

9

12

Interlock Disabled

Interlock

Output

Run/Stop

Output

Program

Interlock

Input

Interlock

Input

J3A

J3B

Interlock Input

Options

+24V

4

1

9

12

Switch Contact

(Open = Interlock)

+24V

4

1

9

12

Logic Input

(0=Interlock)

Advertising