Model 494.44 two-station system board, About the model 494.44 two-station system board, Model 494.44 two-station system board 84 – MTS FlexTest Models 200 User Manual

Page 84: About the model 494.44 two-station system board 84, Board features

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 494.44 Two-Station System Board

FlexTest Controller Configurations

84

Model 494.44 Two-Station System Board

About the Model 494.44 Two-Station System Board

The Model 494.44 System Board is a two-
slot board that is only used in the Model
494.04 Chassis. This board provides analog
and digital I/O, E-Stop, HSM, and HPU
control for two stations.

Board features

External Interfaces

Eight digital inputs (J54*)

Eight digital outputs (J55*)

Auxiliary power outputs for external
devices (J49)

Two analog outputs (DA Output
connector on the 494.04 chassis)

Hydraulic Control

24-volt HPU control (J25)

24-volt HSM control (Off/Low/High
or proportional) for two HSMs (J28)

E-Stop/Interlock Control

Load-frame E-Stop and crosshead
control for two load frames (J29A and
J29B)

Optional E-Stop inputs (J24-located
on the 494.04 chassis)

Two connectors (J43 A and J43B)
each provides one interlock input, one
interlock output, and a software-
defined event input

E-Stop/Run outputs (J23)

J55 Dig Out

Dig In J54

J43A

J43B

J49 Aux Pwr Estop/Run J23

Interlock

J29A

J29B

Load Frame

J28 HSM A-B

HPU J25

Power

100-240 VAC

50-60 Hz, 1-2 A

DA Output

J24

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

LAN 2

LAN 1

DEBUG

MOT

O

ROLA

10/100 BASE T 10/100 BASE T

SCSI

BUSY

PIB

BUSY

PCI MEZZANINE CARD

PCI MEZZANINE CARD

J55 Dig Out

Dig In J54

J43A

J43B

J49

Aux Pwr

Estop/Run J23

Interlock

J29A

J29B

Load Frame

J28 HSM

A-B

HPU J25

J49 AUX PWR
Auxiliary DC supply
voltages for external
devices.
+ 5 V DC, +15 V DC,
-15 V DC, +24 V DC

J28 HSM
24-volt control for
HSM off/low/high or
proportional
solenoids

J43
Interlock input
Interlock output
Event input

J29
Load Frame E-Stop

J25
24 V DC HPU
control

J54*
Digital inputs (8)

J55*
Digital outputs (8)

Model
494.04

Chassis

J23
Estop/Run
2 Estop outputs
2 Run outputs

DA Output (2))

J24 E-Stop
(Optional)

*

Digital inputs (J54)

and digital outputs
(J55) require a
Model 494.32 DI/O
Breakout Box.

* Digital input and output
signals must be routed
through a Model 494.32
DI/O Breakout Box that
includes drivers and
connections for external
devices.

Advertising