Cable specification, Jumper plug required, J24 e-stop – MTS FlexTest Models 200 User Manual

Page 89

Advertising
background image

Model 494.44 Two-Station System Board

MTS FlexTest® Models 40/60/100/200 Controller Hardware

FlexTest Controller Configurations

89

J24 Emergency Stop Connections for the Model 494.44 System Board

The Model 494.44 System Board provides two optional E-Stop inputs that are
available on the J24 E Stop connector (located on the rear panel of the Model
494.04 Chassis).

Cable specification

To maintain EMC compliance, the J24 E-Stop cable must comply with the
following specifications:

Connector type–15-pin, type D, male EMI connector.

Backshell–EMI metallized plastic or metal.

Cable–24 AWG 4-conductor with braided shield, with the braid connected to a
metallized plastic backshell at the chassis and to ground at the emergency stop
(E-Stop) box.

Jumper plug required

If connector J24 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug part number 039-713-201 or jumper
pins 5-7 and 8-13.

494.04 Chassis

494.44 System

Board

J24 E-Stop

Power

100-240 VAC

50-60 Hz, 1-2 A

DA Output

J24

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

LAN 2

LAN 1

DEBUG

MOT

O

ROLA

10/100 BASE T 10/100 BASE T

SCSI

BUSY

PIB

BUSY

PCI MEZZANINE CARD

PCI MEZZANINE CARD

J54

Dig In

J55 Dig Out

J43 INTLK

J56 UPS

J49

Aux Pwr

J23 Estop/Run

J29 Load Frame

J25 HPU

J28 HSM

J24

8

13

5

7

E-Stop Box