Cable specification – MTS FlexTest Models 200 User Manual

Page 94

Advertising
background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 494.44 Two-Station System Board

FlexTest Controller Configurations

94

J29 A/B Load Frame Connections for the Model 494.44 System Board

Connector J29 A/B Load Frame provides interfaces to connect up to two load
frames and optional UPS (J29A only).

Cable specification

To maintain EMC compliance, the J29 A/B Load Frame cable must comply
with the following specifications:

Connector type–15-pin, type D, male EMI connector.

Backshell–EMI metallized plastic or metal.

Cable–18 AWG 8-conductor with foil shield, with the drain wire connected to a
metallized plastic backshell at the chassis.

HPU E Stop 2**

To HPU E Stop Chain

Controller Interlock
Open = Controller Interlock

494.44 System Board

Fused 24 V DC
to Crosshead

J29 A/B

L Frame

1

4

3

2

7

5

8

13

11

15

12

14

9
6

10

Crosshead Interlock
Common

+24V

External Program
Interlock Source
Open=Program Interlock

HPU E Stop 1

+24V

HSM High

Crosshead Unlock Power
Crosshead Unlock
Power Common

Load Frame

J29A J29B

Power

100-240 VAC

50-60 Hz, 1-2 A

DA Output

J24

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

LAN 2

LAN 1

DEBUG

MOT

OROLA

10/100 BASE T 10/100 BASE T

SCSI

BUSY

PIB

BUSY

PCI MEZZANINE CARD

PCI MEZZANINE CARD

J55 Dig Out

Dig In J54

J43A

J43B

J49

Aux Pwr

Estop/Run J23

Interlock

J29A

J29B

Load Frame

J28 HSM

A-B

HPU J25

UPS AC Fail*

UPS

Open=Logic1=Active

Open=Logic1=Active

UPS Battery Low*

* UPS Inputs

are only available

on connector J29A

Load

Frame

Note: A custom Y Cable
(PN 100-197-651) is
required for UPS systems.

To HPU E Stop Chain

** MTS Model 505 Pumps and older

do not use the HPU E-Stop 2 signal.