Series 685 Grip Supply Installation Procedure
Series 685 Grip Supply Product Information
Installation
31
4. Remove the 1/2 inch NPT plug.
The plug was installed in the top of the reservoir for shipment from the
factory.
5. Check the fluid in the reservoir.
The reservoir contains 8.3 liters (2.2 gallons) when the fluid is up to the
“High” mark on the sight gage and 6.1 liters (1.6 gallons) when the level is
at the “Low” mark.
Add fluid to the reservoir as necessary to bring the fluid level to or near the
“High” mark on the sight gage. An extra gallon is shipped with the
hydraulic grip supply. Never add another fluid other than Mobil 525 SHC to
the reservoir.
6. Install the breather.
100 V / 50 Hz / 1 phase
100 V
Common
110 V / 50 Hz / 1 phase
110 V
Common
200 V / 50 Hz / 1 phase
200 V
Common
220 V / 50 Hz / 1 phase
220 V
Common
240 V / 50 Hz / 1 phase
240 V
Common
C
USTOMER
-S
UPPLIED
P
OWER
L1
L2
Sight gage
NPT/Breather