Protocol converter model a/s-4 – Black Box PROTOCOL CONVERTER A/S-4 User Manual

Page 17

Advertising
background image

PROTOCOL CONVERTER MODEL A/S-4

16

Switch Bank S5, Switch:

1-On connects pin 2 of connector to A/S-4’s output of

Transmit Data, for attaching DCE devices

2-On connects pin 3 of connector to A/S-4’s output of

Transmit Data, for attaching DTE devices

3-On connects pin 2 of connector to A/S-4’s input of

Receive Data, for attaching DTE devices

4-On connects pin 3 of connector to A/S-4’s input of

Receive Data, for attaching DCE devices

5-On connects pin 4 of connector to A/S-4’s output of

REQUEST-TO-SEND, for attaching DCE devices

6-On connects pin 5 of connector to A/S-4’s output of

REQUEST-TO-SEND

7-On connects A/S-4’s REQUEST-TO-SEND to A/S-4’s

CLEAR-TO-SEND so that no external signals are needed.
Used for Burroughs TDI and non-hardware throttle devices

8-On connects pins 4 and 5 of connector so external devices

throttle itself

Switch Bank S7, Switch:

1-On supplies internal clocking for A/S-4’s input of

Transmit Clock

2-On connects pin 17 of connector to A/S-4’s input of

Receive Clock, for synchronous operation

3-On supplies internal clocking for A/S-4’s input of Receive Clock
4-On connects pin 20 of connector to A/S-4’s output of

DATA-TERMINAL-READY, for attaching DCE devices

5-On connects pin 20 of connector to A/S-4’s input of

CARRIER DETECT

6-On supplies 1X clock for internal modem port use

7, 8, 9 and 10 reserved

Switch Bank S6, Switch:

6-On supplies 16X clock for internal modem port use, for synchronization of synchronous data over

async modems