Annually

Monthly

Weekly

Daily

Calendar Time using 8 hour
Running Time rate per day

10,000

5,000

2,000

1,500

1000

500

160

40

8

Running Time-Hours

MTS

Determine if replacement or
rebuild of pump
required

Footnote.

MTS

Determine if replacement or
rewind of motor is
required

Footnote.

MTS

Recommend hydraulic fluid
change & clean pump inlet
strainer

Models 505.60/.90/.120/.150/.180 HPU
Maintenance Schedule

The following table lists the recommended interval for each maintenance procedure.

Maintenance Schedule

How to Do It

When to Do It

What to Do

Check electronic enclosure ventilation.

Before the start of each
day’s testing.

Make daily visual inspections

Check dirty filter indicators.

Look for signs of fluid leakage.

Check the fluid level in the sight gage
and replenish as required.

Check system operating pressure and
adjust as required.

Compare the condition of the fluid to that
of your sample, including odor and color.

Every 40 hours or 1
week (whichever occurs
first).

Check fluid quality and condition

Depress Emergency Stop button(s) to
verify that warning and interlock devices
are functioning properly.

Every 40 hours or 1
week (whichever occurs
first).

Check functionality of warning
and interlock devices

*

Generally, an inspection would be done every 10,000 hours. Replacement/repair is typically done at 30,000
hours.

74 Series 505G2 SilentFlo™ Hydraulic Power Unit Product Information

Maintenance