General Specifications
PARAMETER
SPECIFICATION
Operating pressure
21 MPa (3000 psi)
Maximum average full flow
*
(high
pressure mode)
* With dual 56 L/min (15 gpm) servovalves.
114 L/min (30 gpm)
Maximum peak flow
182 L/min. (48 gpm)
Pressure drop through manifold
(less filter)
<0.7 MPa @ 114 L/min (<100 psi @ 30 gpm)
Filtration (optional)
3 micron (Beta3 = 75) or 10 micron (Beta7.4 = 75)
THE FOLLOWING ONLY APPLY TO THE MODEL 298.11
On/off solenoid valve
0 V DC= Off 24 V DC= On
THE FOLLOWING ONLY APPLY TO THE MODEL 298.12
Variable low pressure setting
†
† Adjustable at the controller.
0.7 to 7 MPa (100 to 1000 psi)
Low-to-high, high-to-low ramp
time
†
2 to 5 seconds
Ramp time for rapid shutoff
550 ms
Maximum pressure transient
0.7 MPa (100 psi)
Maximum current to the electrical
pressure reducing valve
0.8 A