Bradford White Everhot TG-150I-N(X) User Manual

Page 55

Advertising
background image

55

°F

Set Temperature

In Use

Priority

e n d l e s s h o t w a t e r s y s t e m

CAUTION: Hotter water increases the risk
of scald injury. Before changing temperature
setting, see instruction manual.

C O R P O R A T I O N

R

P

o

B

Pri rity

utton

Temperature

Display

In Use

Indicator

Priority

Button

Priority

Indicator

Thermostat

Figure 44.

Remote Control and the Description of Functions on All Controls.

Residential Control, p/n 239-47806-00

Commercial Control, p/n 239-47805-00

Installation of Remote Control(s) (Optional)

1. The optional remote controls are intended to be installed in a bathroom close to a shower or tub.

The controls may be wired in parallel only.

2. Mark the holes on the wall using the control mounting plate and drill two mounting holes using a

3/32” (2.4 mm) drill bit and a clearance hole for the cable using a ¼” (6.4 mm) drill bit.















3. Run the cable from the control to the water heater or another control, whichever is closer or more

convenient.

4. Remove the face plate from the remote control by inserting a screwdriver in the slot and twisting

open.

5. Connect the cable to the terminal screws of the remote control.

securing screw

1-21/32"

3-5/16"

securing screw

wiring hole

Figure 45.

Outline of Remote Control's Mounting Plate.

Advertising
This manual is related to the following products: