PAGE 22 — MVC77 PLATE COMPACTOR — OPERATION AND PARTS MANUAL — REV. #4 (1/14/11)

Pump Storage

For storage of the pump for over 30 days, the following is
required:
 Drain the fuel tank completely.
 Run the engine until the fuel in the injection system is

completely consumed.

 Completely drain the oil from the engine crankcase and

follow procedures described in the

HONDA engine

Owner's Manual for engine storage.

 Completely drain the compactor's hydraulic oil from the

vibrating case.

 Clean entire plate compactor, especially the bottom plate

removing all dirt and foreign matter.

 Cover plate compactor and engine with plastic covering

or equivalent and store in a clean, dry place.

PREPARATION FOR LONG-TERM STORAGE