FIG.45 SOLENOID TERMINALS

P1327

SERVICE (cont.)

SOLENOIDS

R2

2

FIG. 44 SOLENOIDS

P1342

Location:

The solenoids are mounted on a bracket that is

attached on top of the chassis on the left side.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white/black wire from the solenoid

to be tested and the orange wire from the left
solenoid, the violet wire from the right solenoid or
the white/violet wire from the center solenoid.

3. With a voltmeter, check the voltage across the

white/black wire and the other wire with the ON/
OFF switch in the “ON” position and the appropri-
ate ICE/OFF/NO-ICE switch in the “ICE” or “NO-
ICE” position. Connect the dispenser to the power
source. The indication must be:
a) 120 volts ac for 120 volt models.
b) 230 volts ac for 230 volt models.

4. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the

Wiring

Diagram

and check the dispenser main wiring harness.

5. Check for continuity across the solenoid valve coil

terminals.

If continuity is present as described, reconnect the
wires to the solenoid.

If continuity is not present as described, replace the
solenoids.
6. Check the solenoid valve for coil action. Connect

the dispenser to the power source. With the auger
motor switch in the “ON” position and the ON/OFF/
ICE switch in the “ICE” or “NO-ICE” position press
the ON/OFF switch to the “ON” position. After
approximately two minutes listen carefully in the
vicinity of the solenoid valve for a “clicking” sound
as the coil magnet attracts.

7. Disconnect the dispenser from the power source.

If the sound is heard as described and the refrigerant
will not pass through the solenoid valve, there may
be a blockage in the refrigerant line before the sole-
noid valve, or the solenoid valve may require inspec-
tion for wear, and removal of particles.

If the sound is not heard as described, replace the
solenoids.

Removal and Replacement:

NOTE: Before removal of any refrigeration component
the refrigerant in the system must be reclaimed by a
licensed refrigeration repair person.
1. Disconnect the wires from both solenoids.
2. Disconnect the refrigerant lines from the sole-

noids to the cooling drums and the refrigerant line
from the accumulator.

3. Remove the #6 hex crimptite securing solenoid

bracket to the dispenser chassis.

4. Remove bracket and solenoids from the chassis

assembly.

5. Remove the four #8-32 locking screws securing

the solenoids to the bracket.

6. Remove solenoid and repair or discard.
7. Install new solenoid on mounting bracket using

four #8-32 locking screws.

8. Reinstall mounting bracket and solenoids inside

the dispenser chassis, securing with a #6 hex
crimptite screw.

9. Reconnect the tubes from the accumulator and the

cooling drums.

10. Refer to Fig. 45 and reconnect the wires.
11. Evacuate the system.
12. Recharge the system with the appropriate coolant

and to the pressures directed on the decals

NOTE: The charging of the system must be done by a
licensed refrigeration repair person.

27646 122200