Specifications – Multiquip DCA70SSIU User Manual
Page 12

PAGE 12 — DCA70SSIU 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (01/06/09)
Generator Specifi cations
Table 1.
Model
DCA-70SSIU
Type
Revolving fi eld, self ventilated,
open protected type synchronous generator
Armature Connection
Star with Neutral
Zigzag
Phase
3
Single
Standby Output
58.8 kVA (47 kW)
34 kW
Prime Output
56 kVA (44.8 KW)
32 KW
Power Factor
0.8
1.0
Voltage
200 or 400V
100 or 200V
Frequency
50 Hz
Speed
1500 rpm
Aux. AC Power
Single Phase, 50 Hz
Aux. Voltage/Output
4.8 Kw (2.4 kW x 2)
Engine Specifi cations
Table 2.
Model
ISUZU FF-4BG1T
Type
4 cycle, water-cooled, direct injection, turbo-charged
No. of Cylinders
4 cylinders
Bore x Stroke
4.13 in. x 4.92 in. (105 mm x 125 mm)
Displacement
264 cu. in. (4,329 cc)
Starting
Electric
Coolant Capacity
3.43 gal. (13.2 liters)
Lube Oil Capacity
3.49 gal. (13.2 liters)
Fuel Type
#2 Diesel Fuel
Fuel Tank Capacity
40 gal. (150 liters)
Fuel Consumption
3.6 gal. (13.6 L)/hr at full load
Battery
27(CCA 0° F 700A) X 1
SPECIFICATIONS