IndOOR InsTaLLaTIOn

Exhaust gases from diesel engines are extremely

poisonous. Whenever an engine is installed indoors the

exhaust fumes must be vented to the outside. The engine

should be installed at least two feet from any outside wall.
Using an exhaust pipe which is too long or too small can

cause excessive back pressure which will cause the engine

to heat excessively and possibly burn the valves.
Eliminate the danger of deadly carbon monoxide gas.

Remember that exhaust fumes from any gasoline or diesel

engine are very poisonous if discharged in a closed area.
If the light tower is installed indoors, you must make

provisions for venting the engine exhaust to the outside

of the building.

Lamp pOWeR CaBLe COnneCTIOns

1. Locate the 4 key-lock female 3-pin DIN connectors on

the T-bar as shown in Figure 12.

Figure 12. 3-Pin DIN Female Connector

2. Next, locate the slot or key (A) on each female

connector as shown in Figure 12.

3. On the corresponding male connector, locate the key

tab (B) as shown in Figure 13.

Figure 13. Male Connector

A

B

setup

4. Align the key tab (B) on the male connector with the slot

or key (A) on the female connector and press together

until seated. Connect the light power cables to the T-bar

as referenced in Table 7 and Figure 14.

Figure 14. Light Power Cable Connections

5. Secure all cable connectors by screwing the knurled

locking nut of the male connector to the threaded

portion of the female connector to ensure good contact

between the two connectors. See Figure 14.

Table 7. Light power Cable Connections

power Cable

T-Bar Receptacle

Light 1

J1

Light 2

J2

Light 3

J3

Light 4

J4

LIGHT

1

LIGHT 3

LIGHT 2

LIGHT 4

J1

J3

J4

J2

REAR

FRONT

MAST RAISED