UTG Series

Twisted pair cable monocrimp contact cabling

#16 coaxial contacts

Cable reference

Contact

type

Male

contact

Female

contact

Crimp

tool

Die

set

Stop

bushing

Cable strip

length

Inner conductor

crimp

Braid crimp

A

B

C

g dim

t dim

g dim

t dim

#28 7/.0036 per Hitachi

spec ec-711 (13-2820)

Mono

crimp

RMDX6031D28

+ YORX090

RCDX6031D28

+ YORX090

M10S1J

S80

SL105

4.7

6.1

4.32

1.30 to

1.12

1.4 to 1.22

2.97 to

2.84

3.07 to 2.9

20218204

S80

SL105

3.94

6.1

3.16

1.30 to

1.17

1.4 to 1.22

2.97 to

2.84

3.07 to

2.79

#30 solid

S83

SL105

4.7

6.1

4.06

1.22 to

1.12

1.35 to

1.22

2.97 to

2.84

3.12 to

2.95

#26 7/.0063

S80

SL105

4.7

6.1

4.06

1.30 to

1.17

1.4 to 1.22

2.97 to

2.84

3.07 to 2.9

#26 19/.004

M10SG8 ASSY'Y

TOOL DIE SET
STOP BUSHING

M10S1J TOOL

4.7

6.1

4.06

1.22 to

1.17

1.35 to

1.22

2.84 to

2.79

3.12 to

2.97

#24 7/.008

4.7

6.1

4.06

1.22 to

1.17

1.35 to

1.22

2.84 to

2.79

3.12 to

2.97

#24 19/.005

4.7

6.1

4.06

1.22 to

1.17

1.35 to

1.22

2.84 to

2.79

3.12 to

2.97

AWG26 (19x0.1)

M10SG8

crimping kit

4.7

6

4

AWG24 (7x0.2)

AWG24 (19x0.13)

AWG26 (7x0.16)

S80

SL150

G

G

Braid crimp (G) to be measured

with die set fully closed

Inner conductor crimp (G) to be

measured with die set fully closed

RCDX60

Female coax contact

RMDX60

Male coax contact

See cable strip lengths

Cable strip length

A

B

C

16 min.

• Select appropriate monocrimp coax twisted pair contact and cable combination.
• Select appropriate crimp tooling (hand tool, S-die set, stop bushing).
• Strip the twisted pair cable to the designated wire strip lengths.
• Insert the stripped cable into the contact. One cable is to be inserted into the
inside diameter of hyring, and pushed forwaerd into the inner contact. The
second cable is to be inserted between the outside diameter of hyring and the
inside diameter of the outer contact body.
• Crimp the contact.

Note : all dimensions are in mm