Modular
Technische Kennwerte
Features
Technical characteristics
Han
®
Shielded module
• Data bus shielding separated from housing
• Ideal for the transmission of very sensitive signals
(e.g. bus signals)
Specifications
DIN EN 60 664-1
DIN EN 61 984
Han
®
Module adapter
Number of contacts
20 + shield
Insulation resistance
≥ 10
10
Ω
Material Polycarbonate
Limiting temperatures
-40 °C ... +125 °C
Flammability acc. to UL 94
V 0
Mechanical working life
≥ 500 mating cycles
Shielded insert
Electrical data acc. to
DIN EN 61 984
4 A 32 V 0.8 kV 3
Rated current
4 A
Rated voltage
32 V
Rated impulse voltage
0.8 kV
Pollution degree
3
Material
- Insulator
Liquid Crystaline Polymer
- Outer conductor
Zinc alloy
Contact resistance
≤ 4 mΩ
Limiting temperatures
-40 °C ... +125 °C
Flammability acc. to UL 94
V 0
Outer surface finish
Nickel
Cable diameter
5 ... 12 mm
Han
®
D-Sub crimp contacts
Crimp terminal
- mm²
0.08 ... 0.52 mm²
- AWG
28 ... 20
Turned contacts
Performance level 1
Accessories
Crimp flange
see page 06.98
Crimp ferrule
see page 06.98
Cable clamp
see page 06.98