3.2.1.4

SW6, SW7, SW8 - Link Modes

These three DIP-switches configure the link mode settings. DIP-switch SW6 is valid when Port 1 is set to
“AN” or “MAN”. DIP-switches SW7 and SW8 are ignored when Port 1 is set to “AN”. The following
table details possible Link Mode DIP-switch configurations.

PI

SA

SW1

SW6

SW7

SW8

Result

Left

(AN)

Left

Left

Left

Enables Link Segment mode (LS).

Left

(AN)

Right

Left

Left

Enables Link Propagate mode (LP).

Right

(MAN)

Left

Left

Left

Enables Link Segment mode (LS).

Right

(MAN)

Right

Left

Left

Enables Link Propagate mode (LP).

Right

(MAN)

Left

Right

Left

Enables Remote Fault Detection
mode plus Link Segment mode
(RFD+LS).

Right

(MAN)

Right

Right

Left

Enables Remote Fault Detection
mode plus Link Propagation mode
(RFD+LP).

Right

(MAN)

Left

Left

Right

Enables Symmetrical Fault Detect
mode (SFD).

Right

(MAN)

Right

Left

Right

Illegal Setting, Link Segment (LS) is
selected.

Right

(MAN)

Left

Right

Right

Illegal Setting, Link Segment (LS) is
selected.

Right

(MAN)

Right

Right

Right

Illegal Setting, Link Segment (LS) is
selected.

SW1

SW6

SW7

SW8

Result

Down

(AN)

Down

Down

Down

Enables Link Segment mode (LS).

Down

(AN)

Up

Down

Down

Enables Link Propagate mode (LP).

Up

(MAN)

Down

Down

Down

Enables Link Segment mode (LS).

Up

(MAN)

Up

Down

Down

Enables Link Propagate mode (LP).

Up

(MAN)

Down

Up

Down

Enables Remote Fault Detection
mode plus Link Segment mode
(RFD+LS).

Up

(MAN)

Up

Up

Down

Enables Remote Fault Detection
mode plus Link Propagation mode
(RFD+LP).

Up

(MAN)

Down

Down

Up

Enables Symmetrical Fault Detect
mode (SFD).

Up

(MAN)

Up

Down

Up

Illegal Setting, Link Segment (LS) is
selected.

Up

(MAN)

Down

Up

Up

llegal Setting, Link Segment (LS) is
selected.

Up

(MAN)

Up

Up

Up

llegal Setting, Link Segment (LS) is
selected.

NOTE: Connecting two converters together where both are set to any of the RFD modes is illegal
and will cause a “deadly embrace” lockup.
NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.

For detailed information on the operation of the different Link Modes, download the application note
iConverter Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

3.3

INSTALLING THE MODULE AND CONNECTING CABLES

PI

a.

Carefully slide the module into an open slot in the chassis. Align the module with the installation
guides and ensure that the module is firmly seated against the backplane. Secure the module by fastening
the front panel thumbscrew (push in and turn clockwise to tighten) to the chassis front. Verify the
“Pwr” LED is ON (indicating the chassis is powered).

SA

a.

The Gx AN standalone media converter is available in tabletop and wall-mounting models. For wall-
mounting, attach the Gx AN to a wall, backboard or other flat surfaces. For tabletop installation, place
the unit on a flat and level surface. Attach the rubber feet to the bottom of the Gx AN to prevent the
unit from sliding. Make sure the unit is placed in a safe, dry and secure location.

To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC outlet. Then
connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector
(center-positive) on the unit. Confirm that the unit has powered up properly by checking the power