Setup unit, Warnings, Set p1/set p2 – PLX Devices DM-6 User Manual

Page 2

Advertising
background image

TERMS OF USE

PLX Devices Inc. does not guarantee product functionality

with any ECU, data logger or other devices that uses the

output signals. Implementation and integration of the PLX

products with any other device(s) must be done at your own

risk. Improper installation and usage may lead to engine

damage. Mount and install PLX products in a location

where it does not obstruct the driver’s view and/or ability or

safely control the vehicle.

PLX Devices Inc. does not guarantee product functionality

with ALL vehicles. Implementation and integration of the

PLX products with any other device(s) must be done at your

own risk. Improper installation and usage may lead to en-

gine damage. Mount and install PLX products in a location

where it does not obstruct the driver’s view and/or ability or

safely control the vehicle

LIMITED WARRANTY

PLX Devices Inc. warrants this product to be free from

defects for 1 year from the date of purchase. If applicable,

Oxygen sensors and other non-serviceable items are

excluded from stated warranty. Serviceable goods must

be determined by PLX Devices to be defective before any

warranty or replacement is issued. PLX Devices’ obligation

under warranty shall be limited to repairing or replacing,

under the discretion of PLX Devices, any part proven defec-

tive. This warranty is limited to the repair or replacement

of parts in the manufactured good and the necessary labor

done to affect its repair or replacement.

SERVICE UNDER WARRANTY

In the unlikely event that your PLX Devices hardware

should fail during the warranty period, a Return Material

Authorization number (RMA) must be first retrieved from

PLX Devices Customer Support. Support can be contacted

through e-mail: [email protected] or by phone: 408-

745-7591. All serviceable goods must be packaged securely

with proof of purchase, RMA number, with all shipping

charges prepaid and shipped to PLX Devices Inc. Goods

returned under warranty must be received by PLX Devices

Inc. within ten (10) business days after the RMA number

has been issued. Goods received after this period are subject

to fees for the service of repair or replacement. All repaired

or replaced items shall be warranted for the remainder of

the original product warranty.

RETURNS AND RESTOCKING FEE

All returns must be within 30 days of receipt. A 15%

restocking fee will apply to applicable PLX Devices products

for refund. All returns are to be packed in original condi-

tion including packaging, documentation, manuals, and ac-

cessories. Returns that do not include all the accessories and

components may be returned to the customer or charged

on a per item basis. The customer assumes responsibility

for product until receipt at PLX Devices Inc., shipping via

an insurable carrier is recommended. Any unauthorized

shipping charges will be billed to the customer or shipment

will be refused.

DISCLAIMER

PLX Devices Inc. shall not be liable for direct, special, inci-

dental, or consequential damages resulting from any legal

theory including, but not limited to, lost profits, downtime,

goodwill, damage, injury to persons, or replacement of

equipment and property due to improper installation, inte-

gration and/or misuse of any PLX Devices Inc.’s product(s).

This warranty applies to the original purchaser of product

and is non-transferable. All implied warranties shall be

limited in duration to the said 1 year warranty period.

Physical Dimensions:

Display Technology:

Viewing Angle:

Polarization:

Supply Voltage:

Power Consumption:

Cable Length:

Operating Temp:

Human Interface:

Number of Sensors:

Supported Units:

Standard 2 1/16 x 0.7” (52 X 18 mm)

1.10” OLED Screen (124 x 36 pixels), LED (16 Green, Yellow, Red)

180 Degrees

None

3.3 V and 8 V from SM Module

< 1 Watt

6’ Power, 6” Serial

0 - 85 Degrees Celsius

3 Button Capacitive Touch

16 Maximum Daisy Chain

US Standard, Metric

Specifications:

Included Items:

1. DM-6 2 1/16” (52 mm) Gauge

2. 4 Pin connector for SM-AFR connectivity

3. 2 Terminals for 4 pin Connector

4. 3.5 mm Y Splitter

5. 6” M/F Extension Serial Cable

6. User guide

Setup Unit

To setup the unit for a particular sensor, follow the procedures listed below:

1. Hold both left and right button to get into the “SETUP MENU”.

2. Press the right button to get into “SETUP UNIT” screen.

3. To change the sensor, press the right button.

4. To change the unit for that particular sensor, press the logo button to move down the arrow.

5. Press the right button to change the unit.
6. Press the left button to save and go back to the “SETUP MENU” screen.

Warnings:

The DM-6 can be operated to trigger the warning by setting the limit of the parameters

(Parameter 1(P1) and Parameter 2(P2)). Sensors that are daisy-chained with the DM-6 can

be selected to associate with the parameter setting. The DM-6 is capable of monitoring up to

2 parameters for warnings. To trigger the warning, the reading of the DM-6 must go above or

below the parameter setting as determined by the user. The table below shows the 4 schemes

that are supported by DM-6.

If the DM-6 measures the above values and the “SCHEME” is set to “P1 OR P2”, this means

that if Parameter 1 is TRUE OR Parameter 2 is TRUE, the warning will trigger.

Since EGT is set in Parameter 2 and the measured value exceeds the trigger point set for this

particular sensor, the warning will trigger as soon as the measured value exceeds 800.

The LEDs will be flashing, indicating that the warning has been triggered. DM-6 will also

display the particular sensor that triggers the warning in the numerical mode.

If mode P1 AND P2 is selected, as the warning triggers, you can press the left button to view

the two sensors that trigger the warning.

Mode

Description

P1 and P2

Warning triggers only when the reading falls within the range set by
both Parameter 1

and

Parameter 2

P1 or P2

Warning triggers only when the reading falls within the range set by
Parameter 1

or

Parameter 2

P1 Only

Warning triggers when the reading falls within the range set by

Parameter 1 only

P2 Only

Warning triggers when the reading falls within the range set by

Parameter 2 only

To trigger the warning, first set the “SCHEME”:

1. In the “SETUP MENU”, choose “WARNING” by pressing the logo button.

2. Press the right button to get into the “WARNING” screen.

3. To change the “SCHEME”, press the right button. Refer to the above table for the descrip-

tion for each “SCHEME”.

4. Press the left button to save and return to the “SETUP MENU” screen.

Trigger point settings (SET P1 or SET P2)

DM-6 Reading

Result

Parameter 1: AFR > + 15.0

AFR = 14.0

FALSE

Parameter 2: EGT > + 800

EGT = 900

TRUE

Example:

SET P1/SET P2:

1. In the “SETUP MENU”, choose “SET P1 or SET P2” by pressing the logo button.

2. Press the right button to get into the “SET P1 or SET P2” screen.

3. To select the sensor as the warning sensor, press the right button.

4. To set the trigger value, press the logo button to move down the arrow.

5. Press the right button to change the highlighted character.

6. To highlight the next character, hold on to the right button for 3 seconds.

7. Press the left button to save and return to the “SETUP MENU” screen.

8. If the limit is invalid, the “LIMIT EXCEED RANGE” screen will show to indicate the

proper range of values to be set.

9. Press the right button to re-enter the parameter or press the left button to go back to the

“SETUP MENU” screen.

Advertising