Overview, Specifications – RKI Instruments 65-2434RK User Manual

Page 5

Advertising
background image

65-2434RK CO Transmitter • 1

Overview

This manual describes the 65-2434RK carbon monoxide (CO) transmitter. This manual
also describes how to install, start up, maintain, and calibrate the transmitter. A parts list
at the end of this manual lists replacement parts and accessories for the CO transmitter.

Specifications

Table 1 lists specifications for the CO transmitter.

WARNING: When using the 65-2434RK, you must follow the instructions and warnings

in this manual to assure proper and safe operation of the 65-2434RK and to
minimize the risk of personal injury. Be sure to maintain and periodically
calibrate the 65-2434RK as described in this manual.

Table 1: Specifications

Target Gas

Carbon monoxide (CO)

Sampling Method

Diffusion

Input Voltage

10 VDC - 30 VDC

Signal Output

4 - 20 mA

Detection Range

0 to 300 PPM (parts per million)

Accuracy

± 5% of reading or ± 5 ppm CO (whichever is greater)

Response Time

90% in 30 seconds

Advertising