Model GD-K8A4X Sample Draw Transmitter • 2

Description

This section describes the components of the GD-K8A4X. It consists of the enclosure, the
sensor and amplifier from a GD-K8A, and a wiring terminal strip.

Figure 1: Component Location/Wiring

Enclosure

The enclosure is a type NEMA 4X plastic enclosure designed for use in areas that are
subject to rain or hosing down. A mounting foot is installed in each corner. A hole in the
front door allows the sensor to sample the ambient air by diffusion. A rain shield installed
over the hole protects the sensor from water. A 3/4” conduit hub is located on the bottom
of the enclosure for wire entry.

Sensor/Amplifier

The sensor/amplifier from a GD-K8A is mounted to a sensor plate. The sensor plate is
mounted to a mounting plate with four standoffs. See the GD-K8A Operator’s Manual for
a complete description of the sensor and amplifier.

Wiring Terminal Strip

A three point terminal strip is located near the bottom of the enclosure on the mounting
plate for connections to the controller.

3/4" Condui t Hub

Factory
Us e Onl y

(mA Output)

TP2 (-)

TP1 (+)

Factory Adj us t

Gain Pot (Factory Adjus t)

Zero Pot

Span Pot

Note: Shown W ithout Door

+24 VDC

Wi ring Termi nal
Strip

Sens or

Feedback (-)

Sens or Keeper