Clips & girts – Roxul ComfortBoard CIS User Manual
Page 6

TECHNICAL COMMUNICATION
WWW.ROXUL.COM
6 OF 8
©ROXUL INC 2013
1.
GENERAL
Proprietary clips / brackets or non-
proprietary stand-offs designed to support
vertically installed z-girts or L-channels can
be used. Insulation is not required to provide
any structural support with this type of
system.
2.
THERMAL BRIDGING & Z-GIRTS
ROXUL does NOT recommend using z-girts
through the full thickness of insulation.
Clips, brackets or stand-offs should be used
to minimize thermal bridging.
3.
DESIGN
Z-girts and fastening system should be
designed to support wind loads and total
applied dead loads independently of the
insulation.
If clips & girts do NOT provide structural
support to the insulation it should be
fastened per directions for Plain Insulation.
If clips & girts provide structural support to
the insulation then designers can reduce the
required number of fasteners appropriately.
4.
CASCADIA CLIPS & OTHER
PROPRIETARY SYSTEMS
Follow manufacturers recommendations
5.
FASTENERS
Fasteners should be appropriate type for
the substrate
Use the manufacturers recommended
fasteners when using proprietary clips &
brackets
Anti-unwinding fasteners (or alternative
precautions) should be used for metal
frame construction and metal-to-metal
fastening of clips & girts.
Fasteners for attaching insulation
Impaling Pins
Screws & Washers
Plastic Cap Nails
Insulation Fasteners
Clips & Girts
ISSUED: 04-15-14 SUPERSEDES 04-11-14