1.

GENERAL

Proprietary clips / brackets or non-
proprietary stand-offs designed to support
vertically installed z-girts or L-channels can
be used. Insulation is not required to provide
any structural support with this type of
system.

2.

THERMAL BRIDGING & Z-GIRTS

ROXUL does NOT recommend using z-girts
through the full thickness of insulation.
Clips, brackets or stand-offs should be used
to minimize thermal bridging.

3.

DESIGN

Z-girts and fastening system should be
designed to support wind loads and total
applied dead loads independently of the
insulation.
If clips & girts do NOT provide structural
support to the insulation it should be
fastened per directions for Plain Insulation.
If clips & girts provide structural support to
the insulation then designers can reduce the
required number of fasteners appropriately.

4.

CASCADIA CLIPS & OTHER
PROPRIETARY SYSTEMS

Follow manufacturers recommendations

5.

FASTENERS

 Fasteners should be appropriate type for

the substrate

 Use the manufacturers recommended

fasteners when using proprietary clips &
brackets

 Anti-unwinding fasteners (or alternative

precautions) should be used for metal
frame construction and metal-to-metal
fastening of clips & girts.


Fasteners for attaching insulation
 Impaling Pins
 Screws & Washers
 Plastic Cap Nails
 Insulation Fasteners

Clips & Girts