S&S Cycle 49-State Certified X-Wedge Engines User Manual
Page 11

11
6- Confirm the terminals are all in proper alignment and reinstall the clear plastic cover. Next, close the cover of the 36-position connector, making
sure to get all the clips back in place. Finally, reinstall a wire tie at the base of the 36-position connector. See Picture 20.
Bank Angle Sensor
A bank angle sensor input to the ECU is required for the engine to run. It is recommended a Harley-Davidson® bank angle sensor be used.
Recommended Parts Used:
H-D® # 72399-98 Connector – 3 way
•
(3) H-D #72033-93 Socket Terminal
•
H-D #32495-98 Bank Angle Sensor
•
H-D #72326-95 ECM Terminal
•
Recommended wire colors:
•
- LTGN/Gy, Bank Angle Signal
-BK, Chassis GND
-Gy, Switched Ignition Power
This sensor must be mounted with the connector end facing downward and with the cast H-D® part number facing either the front or the back of
the motorcycle, as shown in Picture 21.
The bank angle sensor connections, from the 3-way connector at the sensor, are as follows:
A: Bank Angle Signal, LTGN/Gy, to pin 9 of ECU
•
B: Chassis GND, BK, to chassis ground
•
C: Switched Ignition Power, Gy, to switched power source
•
Picture 20