Chapter 1 Introduction

2

• Programmable Controller (32 control setpoints, OR/AND logic,

extensive triggers, programmable thresholds and delays, relay
control, event-driven data recording). Ability to block relay outputs
with a special control algorithm.

•

High-Class 3-phase Power meter (true RMS, volts, amps, powers,
power factors, unbalance, neutral current)

•

Demand Meter (amps, volts, harmonic demands)

•

Precise Energy and Power Demand Meter (TOU, 16 Summary
energy and demand registers for substation energy management,
accumulation of energy pulses from external watt-meters, block
and sliding demands, up to 64 energy sources)

•

Harmonic Analyzer (to 63rd harmonic volts and amps, directional
power harmonics and power factor, phasors, symmetrical
components)

•

32 digital counters for counting pulses from external sources and
numerous internal events

•

16 programmable timers from 1/2 cycle to 24 hours for periodic
recording and triggering operations on a time basis

•

1-ms satellite-synchronized clock (IRIG-B time-code input)

•

SNTP Time Synchronization thru Ethernet port.

•

Second backup power supply unit.

Additionally, the SA300 can be equipped with a 64/128-Mbyte Expansion Memory plug-in module for long-
term waveform recording.

AC/DC Inputs

The SA300 is provided with a set of fully isolated AC/DC inputs for a connection to the AC feeders and station
battery:

•

Four isolated AC voltage inputs (up to 690VAC direct line-to-line input voltage)

•

Four standard isolated AC current inputs with an extended input range up to

×3000%

overload (10A/IEC or 20A/ANSI input currents, to 150 Amps fault currents)

•

Optional second set of four isolated current inputs (10A/IEC or 20A/ANSI input currents)
for precise energy metering

•

DC voltage input (up to 300VDC) for monitoring the station battery

Digital and Analog I/O Options

The SA300 has five I/O expansion slots for removable plug-in I/O modules:

•

DI - Digital inputs (16 or 32 optically isolated inputs per module, up to 3 modules per
device; options for dry contacts, and wet inputs; programmable de-bounce time from 1
ms to 1 sec; free linkage to Sequence-of-Events Recorder, Fault Recorder, control
setpoints, pulse counters and Energy/TOU subsystem)

•

RO - Relay outputs (8 or 16 relays per module, up to 4 modules per device; unlatched,
latched and pulse operations, failsafe operation for alarm notifications; programmable
pulse width; direct remote relay control through communications)

•

AI/AO - Mixed analog input/output modules (four optically isolated AI and four AO with
internal power supplies per module, up to 4 modules per device; options for 0-1mA,
±1mA, 0-20mA and 4-20mA inputs and outputs;

×200% overload current for 0-1mA and

±1mA AI/AO)

Communications Options

The SA300 has extensive communications capabilities:

•

Three independent universal serial communications ports (RS-232, RS-422/RS-485,
up to 115,200 bps, Modbus RTU/ASCII and DNP3.0 protocols)

•

Infrared port (Modbus RTU/ASCII and DNP3.0 protocols)

•

Embedded 56K modem for communications through public telephone lines (Modbus
RTU/ASCII and DNP3.0 protocols)

•

Ethernet 10Base-T port (Modbus/TCP or DNP3.0/TCP protocols, up to five non-
intrusive simultaneous connections, Telnet service port)

•

USB 1.1 port (Modbus RTU protocol, 12 Mbps) for fast local communications and data
retrieving