Step 4, Step 5, Step 6 – Schwank IEP-1524 User Manual

Page 16: Step 7, Step 8, Heat lamp replacement

Advertising
background image

16

IM110810

RD: AUGUST 2011

RL; 1A

BA

InfraSave IEP-1524 Manual

Heat Lamp Replacement

:

continued

Step 4

Remove 2 Phillips screws that fasten the connection box
face plate in place.




Step 5

Disconnect electrical supply cord spade connectors from
terminals.






Step 6

Loosen 2 screws in terminal block that connect the red
heat lamp wires in place. Remove ends of red wires from
terminal block.

6A - Loosen plastic collar on Liquid Tight Connec-

tor that secures red wires to connection box.



Step 7

Slide power cord retainer plate from heater body (top sur-
face of heater).




Step 8

Loosen plastic collar on second Liquid Tight Connector
that secures red wires through connection box end plate.

Slide red wires out of connection box.
Set connection box aside.

6A

Connection

Box

Heater

Body

Advertising