IM110810
RD: AUGUST 2011
RL; 1A
BA
InfraSave IEP-1524 Manual
Heat Lamp Replacement
:
… continued
Step 4
Remove 2 Phillips screws that fasten the connection box
face plate in place.
Step 5
Disconnect electrical supply cord spade connectors from
terminals.
Step 6
Loosen 2 screws in terminal block that connect the red
heat lamp wires in place. Remove ends of red wires from
terminal block.
6A - Loosen plastic collar on Liquid Tight Connec-
tor that secures red wires to connection box.
Step 7
Slide power cord retainer plate from heater body (top sur-
face of heater).
Step 8
Loosen plastic collar on second Liquid Tight Connector
that secures red wires through connection box end plate.
Slide red wires out of connection box.
Set connection box aside.