Page 9
SP-M110-CX-05B
1100 Manual
R.D.: March 2006
R.L.: 5B
KH
MODEL
Front and rear of
heater
< F >
Below heater
< G >
Front of heater
< L >
1110
1115
1120
1130
30
”
30
”
33
”
36
”
90
”
96
”
100
”
105
”
66
”
66
”
69
”
72
”
Diagram 3: horizontal mounted
Diagram 4: angle mounted up to 30º
8.3 MINIMUM CLEARANCES TO COMBUSTIBLES
8.4 MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances to combustibles are established at points reaching a surface temperature of 160
0
F.
Some materials such as awnings or plastic may require higher distances. Respect clearances as shown
Table 2:
< 48” >
< 48” >
FRONT VIEW
< F >
<16” >
< G >
< F >
< 48” >
< 48” >
< 24” >
< 8” >
< G >
< L >
Advertising