Schwank patioSchwank 1100 User Manual

Page 9

Advertising
background image

Page 9

SP-M110-CX-05B

1100 Manual

R.D.: March 2006

R.L.: 5B

KH

MODEL

Front and rear of

heater

< F >

Below heater

< G >

Front of heater

< L >

1110
1115
1120
1130

30

30

33

36

90

96

100

105

66

66

69

72

Diagram 3: horizontal mounted

Diagram 4: angle mounted up to 30º

8.3 MINIMUM CLEARANCES TO COMBUSTIBLES

8.4 MINIMUM CLEARANCES TO COMBUSTIBLES

The clearances to combustibles are established at points reaching a surface temperature of 160

0

F.

Some materials such as awnings or plastic may require higher distances. Respect clearances as shown

Table 2:

< 48” >

< 48” >

FRONT VIEW

< F >

<16” >

< G >

< F >

< 48” >

< 48” >

< 24” >

< 8” >

< G >

< L >