Schwank ATH Brooder/Agricultural Series User Manual

Page 20

Advertising
background image

GP-MATH-BX-10A

ATH / IA Manual

RD: Nov, 2005

RL: 10

KH

Page 15

Page 16

16. LIGHTING INSTRUCTIONS

Refer to the lighting instructions on the inside cover of the burner housing. Again, if the unit
goes off on safety, main power to the unit must be manually interrupted for a 30 second reset
period before the heater can be restarted.

NOTE:
On initial installation, the unit may lock out on safety owing to the length of time
required to bleed air from the gas piping system

.

LIGHTING SEQUENCE:

Rotate gas valve knob to ON position.

Set Thermostat to the desired setting.

Turn Power ON to heater.

This should start the Blower, sending the DSI Control into its pre-purge cycle, then into ig-
nition, and light off.

If heater fails to light, shut down heater and wait 5 minutes before relighting it

To shut down the heater just reverse the previous steps.

17. RECOMMENDED MAINTENANCE

THE ATH / IA TUBE HEATER BURNER IS COMPLETELY FACTORY ASSEMBLED
AND TESTED. ANY ALTERATION VOIDS THE CSA CERTIFICATION AND MANU-
FACTURERS WARRANTY. FOR ADDITIONAL INFORMATION, CONTACT YOUR
LOCAL DISTRIBUTOR OR THE MANUFACTURER.

Each 10’ section of the ATH / IA Series Heater is hung by 4 chains, supporting 2 brack-
ets, 2 tubes and one reflector. The heater may be hung at an angle up to 45° providing
the Burner Tube is in the lower position and the flue end in the upper position.

1. Inspect the venting system each heating season and repair or replace worn parts as required.
2. Check the inlet air opening and the blower periodically, cleaning off any lint or foreign mat-

ter, as it is important that the flow of combustion and ventilation air must not be obstructed.
In addition we recommend the entire system be checked once a year by a qualified service
technician.

3. Lubricate Blower motor, by adding several drops of oil to oil ports located on the left hand

side of the motor.

Advertising