Tractor Interface Module Installation Guide

4. 821-7000- RS232 Cable ONLY

Install the RS232 cable between the TIM and the g3 OBC.

Both power and serial communications are run through this
cable (eliminates the need for a separate power cable).

4a. Plug the 9 pin D end of the cable to the TIM and tighten

the thumb screws.

4b. Connect the 6 pin round DIN connector to the BLACK

insulated 6 pin DIN connector that comes out of the
breakout connector of the PeopleNET OBC and tighten
the locking thumb nuts together by hand.

DO NOT connect the Tractor Interface Module to the

Red

or

Blue

or

Yellow

insulated connectors. Use only the Black

insulated connector (g3 services port).

4. 821-7001- USB Cable ONLY

Install the USB cable between the TIM and the g3 OBC.

Both power and serial communications are run through this
cable (eliminates the need for a separate power cable).

4a. Plug the 9 pin D end of the cable to the TIM and tighten

the thumb screws.

4b. Connect the USB connector to the USB port on the g3.

The port is located right behind the cellular antenna
connector; (you may have to remove a piece of silver
tape covering it). USB Symbol on plug faces towards
the cellular antenna connector.

5. Configuring the g3 services port on

the PeopleNET OBC terminal display.

To allow the BatRF TIM to communicate with the PeopleNET
g3 services port, the port must be assigned and configured
using the PeopleNET in cab keyboard and display. Follow
the instructions for the Classic LCD Display or Tablet/BLU/
BLU II as appropriate.

NOTE – For RS232 connected TIMs (821-7000) follow
the instructions on page 5; for USB connected TIMs
(821-7001) follow the instructions on page 6.

USB Port