Components and measurement values – Summit WMC64P Service Manual User Manual

Page 19

Advertising
background image

Service manual WM70.C

19

Components and measurement values

Item
number

Component

Measurement value

Comment

80 658 33

CIM motor

Resistances:
Pins 1-3 stator 3.7 Ω
Pins 1-2 stator 3.6 Ω
Pins 2-3 rotor 3.6 Ω
Pins 4-5 tacho 178 Ω

80 617 03
80 617 04

Heating element 2000
W
Heating element 1000
W

80 761 02

Thermistor

6.1–3.8 kΩ (at room
temperature 20–30°C)

The thermistor for measuring temperature
is located between the motor cradle and the
drum. The thermistor measures and controls
the water temperature, which can vary from
0 to 92°C. The heater is disconnected if the
thermistor is short-circuited or disconnected
from the programme control card.

88 012 63

Drainage pump 50 Hz

144 Ω

The drainage pump is combined with an
integrated fine filter trap, which can be cleaned
by the user. If the drainage pump has run for 3
minutes during draining, the programme stops,
resets and a fault code is indicated on the display.
The pump has a capacity of 20 litres/minute.

88 012 64

Drainage pump 60 Hz

76 Ω

80 782 21

Level switch

Electromechanical level switch with two levels
(see wiring diagram). Used to indicate levels for
door opening, heat and overflow.

80 762 02

EMC filter 50/60 Hz

680 Ω

The filter eliminates interference to and from
the machine.

80 793 24

Inlet valve

3.7 kΩ ± 0.5 kΩ

Two-way inlet valve, 8 litres/minute

80 798 73

Door lock

122 Ω

The door lock is electromechanical and
equipped with a magnet.

80 833 15

One-way inlet valve

80 818 07

Motor control

80 806 28 Control unit

80 833 43

Communication unit

80 083 65 Outlet valve

Advertising