Regency Horizon™ HZ30E-1 Gas Fireplace
MAINTENANCE
VALVE ASSEMBLY REPLACEMENT
4) Remove the glass door.
a) Remove the 2 screws shown below at the bottom of the glass
door
.
b)
Swing the door out 45
o
from the bottom and lift up and out.
Faceplate
(4pc style
shown)
Glass Door
Location of screws on access plate
1) Turn the unit off and allow it to cool down to room temperature.
2) Shut off the gas and power supply to the unit.
3) Remove the faceplate or door frame by lifting it up off the glass door.
5) Remove the burner tray cover by lifting up and out as shown below.
* Prior to removing burner - remove crystals, pebbles, spa stones and inner
panels - if installed.
6) Loosen 2 screws at the back of the burner to release it.
7) Remove the burner by sliding it to the right - then lift out.
8) Remove the valve access plate by undoing the 17 outer screws - see
locations below.