Troubleshooting

24

3A0245A

Unit Will Not Shut Off

Perform Pressure Relief Procedure; page 6.
Leave prime valve handle open and power switch OFF.

Troubleshooting Procedure:

Is the prime valve handle in the Prime/Tool Fill/Recirculation

position? Turn prime valve handle to Apply Finish position and

turn unit ON. Does the unit shut off?

Is the inline valve controller or box slide controller triggered?

If so, detrigger the controller. Does the unit shut off?

Replace Prime

Fill Tool reed

switch

NO

Disconnect the reed switch from the transmitter board

in the inline valve controller. Does the unit shut off?

Is an unwanted RF signal present?

If so, use BLOCK mode. Does the unit shut off?

Disconnect the reed switch from the transmitter board

in the box slide controller. Does the unit shut off?

Disconnect the tool fill reed switch from the motor

control board in the pump module control box. Does

the unit shut off?

Is the unit in Pressure Control Mode (asterisk will show on display)

with the box finishing tool attached? If so, switch the unit off for more

than one minute to reset the unit to the default Flow Control Mode.

Does the unit shut off?

NO

NO

NO

NO

NO

Is the unit in Pressure Control Mode (asterisk will show on display)

with the taper or corner finishing tool attached and Inline Valve

Controller triggered? If so, unplug the transducer from the motor

control board. Does the unit shut off?

NO

Replace the motor control board.

NO

END

YES

END

YES

END

YES

YES

YES

YES

Unit is functioning properly.

Reset unit to default Flow

Control Mode.

YES

Bad transducer.

Replace and test a

new transducer.

YES

Replace Prime

Fill Tool reed

switch

Replace Prime

Fill Tool reed

switch