Titus Vertical Basic IOM User Manual
Page 6

Page 6 of 6
2.7.1
Disconnect all power sources before attempting to open the unit. Check all electrical
wiring to ensure the unit is fully isolated.
2.7.2
Unscrew the fan deck and expose the heater(s).
2.7.3
If the thermal cut-out switch is defective, disconnect the electrical wires and unscrew
it from the heater assembly. Obtain a replacement from TITUS and
reinstall.
2.7.4
If the heating element (the spiral resistance wire) is burned out, unscrew the heater
assembly from the fan deck, disconnect the terminals and replace with a new heater
obtained from TITUS.
***When contacting TITUS for replacement parts, always
refer to the complete Model and Serial numbers on the Serial Plate
located on the blower housing.
605 Shiloh Road
Plano, Texas 75074
972-212-4800