6 specifications, 1 physical characteristics, 2 electrical characteristics – Ultralife CH0007 User Manual

Page 22: Specifications, Hysical, Haracteristics, Lectrical

Advertising
background image

CH0007 Operation Manual

Newark, New York | 315-332-7100 | Fax: 315-331-7800

©2010 Ultralife Corporation • www.ultralifecorp.com • All specific subject to change without notice

The information contained herein is for reference only and does not constitute a warrant of performance •

30 SEP 10 UBI-5166 Rev: A

Page 22 of 25

6 SPECIFICATIONS

6.1 Physical Characteristics

Dimension

Measurement

Width

8.4 inches (21.3 cm)

(Including mounting brackets)

Length

27.3 inches (69.3 cm)

Height

14 inches (35.6 cm)

Weight without Cables
and Batteries

36 Lb. (16.3 kg)

Color

Olive Drab Green

Case

CARC coating - MIL-DTL-64159

Display

VFD graphical and LED status displays

Controls

On/Off Toggle Switch, Conditioning Override toggle switch, VFD brightness tog
switch

Typical Charge Time
(UBBL03)

< 2.5 Hours

Mounting Mounting

rails

integrated on back of charger

External
Communication

USB port for software upgrades and remote monitoring

(Additional software and P

required)

Battery Communication

SMBUS V1.1 w/ PEC (Packet Error Protection)

SMBUS Charger Level 3 Compliant


6.2 Electrical Characteristics

Dimension

Measurement

Charger Input Range

21 to 32 volts DC (Low Power Alarm below 22V)

Charger Input Current

40 to 90 Amps (Circuit Breaker Protected at 75A)

Maximum Battery Charge Current

5A

Minimum Battery Charge Current

0.3A

Maximum Charge Voltage

16.8V

Maximum Conditioning Discharge Current

2A

Power Standard

MIL-STD-1275 compliant

Advertising