Bunn LPG LPG-2E User Manual

Page 6

Advertising
background image

6

Problem

Grinder will not start.

Remedy

(A) Plug-in the grinder.
(B) Check the voltage at the wall
outlet with a voltmeter. It must be
120 volts ac for 120 volt models, 100
volts for 100 volt models, and 230
volts for 230 volt models.

(A) Momentarily press the Off/On/
Start switch to the “START”(lower)
position.
(B) Refer to

Service

- Off/On/Start

switch for testing procedures. See
page 14

Press the “Reset” button, located on
rear of the grinder. Listen carefully
for a “click”. This resets the motor
protection circuit and indicates that
an overload may have been encoun-
tered by the motor. (An overload can
occur when something other than
coffee is inserted into the hopper for
grinding). Refer to

Service

- Circuit

Breaker for testing procedure. See
page 9

Refer to

Service

- Timer for testing

procedures. See page 16

Probable Cause

1. No power or incorrect voltage

2. Off/On/Start switch

3. Circuit Breaker (Not applicable on
Model LPG with capacitor)

4. Timer

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
•

Inspection, testing, and repair of electrical equipment should be performed only by qualified service
personnel.

•

All electronic components have ac voltage and dc voltage potential on their terminals. Shorting of

terminals or the application of external voltages may result in board failure.
•

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent.
If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection
at a terminal or crimp.

•

Make certain that all electrical connections are tight and isolated.

WARNING

•

Exercise extreme caution when servicing electrical equipment.

•

Turn power OFF when servicing, except when electrical tests are specified.

•

Follow recommended service procedures.

•

Replace all protective shields or safety notices.

27091 111598

Advertising