Explanation of the functions (part 4) – Waldmann PULSE HFMD version VFC IV - with MFT, Typ I User Manual

Page 21

Advertising
background image

21

Operating Manual Light Control „PULSE HFMD - Vers. IV“

ENG

Explanation of the functions (part 4)

Function 2.1

Sensitivity high

Function to change the sensitivity

of the presence control.

The function is basically set to

„ON”, i.e., the presence sensor has

a normal sensitivity (100%). Small

movements are also detected

within the detection range of the

sensor.

The presence sensor works with

reduced sensibility (approx. 50%) if

the function is set to “OFF”. Small

movements within the detection

range of the sensor are not de-

tected anymore.

The function can be changed on

lights with sensors XXX /P

Function 2.2

Switch-on automatic

Function to admit or to suppress

automatic switch-on with insuf-

ficient light or in case of presence

(semi-automatic).

The default setting of this function

is ”ON”, i.e., the light is automati-

cally switched on in case of pres-

ence or insufficient light.

The light has to be switched on

manually even in case presence

was detected if the switch-on

automatic is inactive.

The function can be changed on

lights with sensors XXX /P

Fig. 3

Key I

Logo

Light

bar
Key II

LED I

LED II

Function 2.3

Dual sensors

Function for the adjustment of the

operating mode when used with

an additional presence sensor

(optional accessories).

The default setting of this func-

tion is “OFF”, i.e., the switch-on

automatic works when a presence

is detected by one of the two

sensors.

Both sensors must detect a pres-

ence to turn on the light if this

function is active.

The function can be changed on

lights with sensors XXX /P

Note: The functions written in

blue

are not available.

Advertising