q

Run all 24VAC wiring thru the square notch on bottom of TPI case.

(See TPI Diagram 3)

q

Incoming 24VAC power must be connected to 24VAC connectors on the bottom right corner of TPI

control.

(See TPI Diagram 3)

q

Connect control wiring to PUMP/TT normally open relay connections (rated for both 24V and 110V

wiring) on the bottom left corner of TPI control.

(See TPI Diagram 3)

q

All and only 110VAC wiring must go through an appropriate chase nipple installed in the knockout at

bottom of TPI case.

q

Be certain to replace TPI cover using Black Screw provided.

A. INSPECTING AND PREPARING THE WATER HEATER

q

Remove the cardboard box, which comes packaged with the heater. It should contain the following:

TPI thermostat, T&P valve and a “Tee”, foamed lid and screws.
B. LOCATION

q

Solid foundation and dry location.

q

Protect heater water lines from freezing.

q

Area free of flammable vapors.

q

Sufficient room to service heater.

q

Not in close proximity to wood burning stove.

q

Where leak will not damage property.

C. PROTECTION FROM WATER DAMAGE

q

Be sure to make provisions to protect area from water damage if a leak should occur in the

tank or connected fittings.

D. RELIEF VALVE

q

Warning: Improper installation will present potential hazard to life and property.

q

Check to be sure that proper relief valve requirements are met.

q

T&P installed as shown in Figures 1 and 2.

q

3/4” discharge pipe – properly protected from freezing and restrictions.

q

No valve between tank and relief valve or in drain line.

q

Provision for hot water discharge from relief valve.

E. INSTALLING THE REMOVABLE HEAT EXCHANGER

q

Heat Exchanger is installed at the factory except for the AL119SL. The following is provided for ser-

vicing.

q

Insert heat exchanger with plastic o-ring housing.

q

WARNING: Plastic o-ring housing must be installed properly. (See Figure 3).

q

For proper installation of Heat Exchanger

See Figure 3.

F. WATER SUPPLY CONNECTIONS (See Figure  & ).

q

Do not over tighten brass threads.

q

Mark the water shutoff for future reference.