WIRING COMPRESSOR (Fig. 5):

8. The compressor’s red wire is connected to (+) 12-volt power source using the fuse provided.
IMPORTANT! The red wire must be connected to a (+) 12-volt power source only when the vehicle
ignition is turned on. This will protect your compressor from running continuously and being damaged if
an air leak develops when the vehicle is not in operation. Suggested connection points are: blower
motor, windshield wiper motor or accessory terminal on the fuse panel. Make sure the connection point
has a wire that is as heavy as the compressor wire.

OPTIONAL: A switch can be installed into the compressor’s red wire. This will permit the driver to
turn-off the system if it is not required.

9. Remove the plastic cap covering the pressure switch located on the side of the air tank. The

compressor’s black wire is connected to one of the terminals of the pressure switch.

10. Connect the short black length of

wire provided to the other
terminal of the pressure switch.

11. The other end of the black wire

is connected to ground; secure
the wire’s terminal to

either the (-) side of vehicles battery
or under any metal body bolt. Make
sure that ground connection is free
of rust and paint.

NOTE: The compressor is now
ready to be used and will
automatically start when the
pressure drops in the tank. The
pressure switch will automatically turn off the compressor when the tank pressure is approximately
110 p.s.i. If the compressor does not shut off after 4 minutes of running time, check all air hose
connections for leaks. Use soapy water or bubble solution on each fitting while the compressor is
pumping. Use a thread sealant if leak persists after tightening.

CAUTION: Do not touch compressor or fittings with bare hands during or immediately after
usage, they will be hot.

IMPORTANT! Compressor is equipped with THERMAL OVERLOAD PROTECTOR. If unit should
shut off automatically during operation, do not attempt to restart compressor. Allow compressor to
cool off for approximately 40 minutes before resuming use.

WARRANTY

Wolo Manufacturing Corporation (“Wolo”) warranties to the original purchaser, for three months from the date of
purchase, that this product is free from defects in workmanship and materials. If there is such a proven defect, Wolo,
at its option, will either repair or replace the item free of charge, if it is returned to Wolo within three months from the
date of purchase together with proof of purchase as described below. Wolo reserves the right to inspect any defect
prior to settling any warranty claim by repair or replacement. This warranty is limited as above provided and Wolo will
not be responsible for fire or other casualty or accident, due to neglect, abuse, abnormal use, modifications, faulty
installation of this product, or natural causes.

ANY EXPRESSED WARRANTY NOT PROVIDED HEREIN IS EXCLUDED AND DISCLAIMED. THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED
TO A TERM OF THREE (3) MONTHS. UNDER NO CIRCUMSTANCES SHALL WOLO BE LIABLE TO PURCHASER OR
ANY OTHER PERSON FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER ARISING OUT OF BREACH
OF WARRANTY OR OTHERWISE.

To obtain warranty service, return the product prepaid, and include the original bill of sale showing the date of purchase.
Provide with the return a brief description of the problem. Also, include with the return a check or money order in the
amount of $10.00 to cover return shipping. Mail to:

Wolo Manufacturing Corp. •

One Saxwood Street, Deer Park, NY 11729

Attn: Warranty Service

E-mail: [email protected]

© 2005 Wolo Mfg. Corp All Rights Reserved.