WARRANTY

Wolo Manufacturing Corporation (“Wolo”) warranties to the original purchaser, for three months from the date of
purchase, that this product is free from defects in workmanship and materials. If there is such a proven defect, Wolo,
at its option, will either repair or replace the item free of charge, if it is returned to Wolo within three months from the
date of purchase together with proof of purchase as described below. Wolo reserves the right to inspect any defect
prior to settling any warranty claim by repair or replacement. This warranty is limited as above provided and Wolo will
not be responsible for fire or other casualty or accident, due to neglect, abuse, abnormal use, modifications, faulty
installation of this product, or natural causes.

ANY EXPRESSED WARRANTY NOT PROVIDED HEREIN IS EXCLUDED AND DISCLAIMED. THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED
TO A TERM OF THREE (3) MONTHS. UNDER NO CIRCUMSTANCES SHALL WOLO BE LIABLE TO PURCHASER OR
ANY OTHER PERSON FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER ARISING OUT OF BREACH
OF WARRANTY OR OTHERWISE.

To obtain warranty service, return the product prepaid, and include the original bill of sale showing the date of purchase.
Provide with the return a brief description of the problem. Also, include with the return a check or money order in the
amount of $20.00 to cover return shipping. Mail to:

Wolo Manufacturing Corp. •

One Saxwood Street, Deer Park, NY 11729

Attn: Warranty Service

E-mail: [email protected]

© 2005 Wolo Mfg. Corp All Rights Reserved.

when the vehicle is not in operation. Suggested connection points are: blower motor, windshield wiper motor or
accessory terminal on the fuse panel. Make sure the connection point has a wire that is as heavy as the
compressor wire. (Fig. 5).

OPTIONAL: A switch can be installed into the compressor’s red wire. This will permit the driver to turn-off
the system if it is not required.

9. Remove the plastic cap

covering the pressure switch.
The compressor’s black wire is
connected to one of the
terminals of the pressure
switch on air tank. (Fig 5).

10. Connect the short black

length of wire provided to the
other terminal of the pressure
switch.

11. The other end of the black wire is connected to ground; secure the wire’s terminal to either the (-) side of

vehicles battery or under any metal body bolt. Make sure that ground connection is free of rust and paint.
Fig. 5.)

NOTE: The compressor is now ready to be used and will automatically start when the pressure drops in the
tank. The built-in reguator will automatically turn off the compressor when the tank pressure is approximately
110 p.s.i. If the compressor does not shut off after 4 minutes of running time, check all air hose connections
for leaks. Use soapy water or bubble solution on each fitting while the compressor is pumping. Use a thread
sealant if leak persists after tightening.

CAUTION: Do not touch compressor or fittings with bare hands during or immediately after usage,
they will be hot.

IMPORTANT! Compressor is equipped with THERMAL OVERLOAD PROTECTOR. If unit should shut off
automatically during operation, do not attempt to restart compressor. Allow compressor to cool off for
approximately 40 minutes before resuming use.