Specifications – Wood’s Powr-Grip MTA6LP6FAC User Manual

Page 3

Advertising
background image

Rev 16.0/10-12

1

MTA4/6LP6FAC: #35097

SPECIFICATIONS

Description:

Designed for use with a crane or other hoisting equipment, MTA4LP6FAC and
MTA6LP6FAC lifters employ vacuum to hold a load for lifting, and they provide
mechanically assisted, manual 90° tilt movements for load manipulation.

Model Number:

MTA4LP6FAC (w/4 pads)

MTA6LP6FAC (w/6 pads)

Lifter Weight:

48 lbs [22 kg]

55 lbs [25 kg]

Maximum Load Capacity:

200 lbs [90 kg]

300 lbs [135 kg]

(based on Per-Pad Load Capacity of 50 lbs [22.5 kg], rated at 16" Hg [-54 kPa]

on clean, smooth, nonporous flat surfaces

1

)

Power Source:

See serial number plate for specific AC voltage, frequency and amperage.

Vacuum Pads:

6" [15 cm] nominal diameter, low profile (Model LP6F), standard rubber, spring-
mounted (¼" [7 mm] travel), with #60 filter screen

Pad Spread:

Minimum

Maximum (to outer edges)

Nominal Length:

13" [330 mm]

39" [991 mm]

Nominal Width:

13" [330 mm]

30" [762 mm]

Tilt Capability:

Manual, 90°, with four-bar tilt linkage that minimizes operator effort and
automatically holds a correctly attached load in the upright or flat position

Vacuum Pump:

Rotary vane type, 2.5 SCFM [71 liters/minute] nominal airflow

Vacuum Reserve:

Vacuum reserve system helps prevent immediate vacuum loss in case of power

failure.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.

Options:

Available

with Model CM3PE2 - 2" [5 cm] Pad Spacers. This option enables the lifter

to handle loads with surface obstructions, such as windows with mullions.
See separate instructions about other options.

Operating Elevation:

Maximum = 8000 feet [2438 meters]

Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when
used and maintained as intended. Vacuum pads, filter elements and other wear-out
items are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more

information. For the D

ISPOSAL OF THE

L

IFTER

after its service life, see INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

Wiring Diagram:

The following wiring diagram is attached for reference in servicing the lifter or
trouble-shooting a deficiency: (120 VAC)

708B-W01 [B-W02]

,

708B-W04 [B-W04]

;

(240 VAC);

708B-W01 [B-W03]

,

708B-W04 [B-W05]

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS

manual only when requirements of a CE Standard are

different

from requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory

in geographical areas where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.

Advertising