Vacuum level on optimal surfaces, Vacuum level on other surfaces, Ift and – Wood’s Powr-Grip FL4HV11AC User Manual

Page 14: Ove the, Load capacity and the lift light

Advertising
background image

Rev 15.0/1-14

12

FL4HV11AC: #35030

Vacuum Level on Optimal Surfaces

When the lifter is attached to clean, smooth, nonporous load surfaces, it should be able to

maintain a vacuum level in the green range on the vacuum gauge, except when used at high
elevations (see SPECIFICATIONS: Operating Elevation). If not, perform the V

ACUUM

T

EST

(see

MAINTENANCE) to determine whether there is a deficiency in the vacuum generating system.

Vacuum Level on Other Surfaces

When the lifter is attached to contaminated, rough or porous load surfaces, it may not be able to

maintain a vacuum level in the green range on the vacuum gauge, due to leakage in the seal
between the vacuum pads and the load surface. In the case of contamination, thoroughly clean
the contact surfaces of the load and the vacuum pads (see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Cleaning), and reapply the lifter to the load. If the load has rough or porous

surfaces,

the operator must conduct a test to determine whether the lifter is designed

to lift the load

, as follows:

1) Make sure the lifter's vacuum generating system is functioning correctly (see MAINTENANCE:

V

ACUUM

T

EST

).

2) Apply the vacuum pads to the load as previously directed.
3) When the vacuum level registers above 16" Hg [-54 kPa] on the vacuum gauge (see T

O

L

IFT

AND

M

OVE THE

L

OAD

: Load Capacity and the Lift Light to follow), place the power switch in the

OFF ( ) position.

4) Raise the load a minimal distance, to assure that it is supported by the lifter.
5) Monitor the vacuum gauge while the load is suspended for 5 minutes:

The lifter must

maintain a minimum vacuum level of 10" Hg [-34 kPa] during this time.

If not, the

load does not possess the characteristics required for using this lifter.

9

T

O

L

IFT AND

M

OVE THE

L

OAD

Load Capacity and the Lift Light

A lifter's Load Capacity is rated at a vacuum level of 16" Hg [-54 kPa] (see SPECIFICATIONS).

After the lifter has attained this level, the green vacuum lift light turns on to indicate that the
lifter is ready to lift the maximum load weight.

WARNING: Never attempt to lift load unless green lift light is illuminated.

Do not attempt to lift the load unless the lift light is illuminated and the lever on the vacuum

control valve is in the “APPLY” position (see T

O

R

ELEASE THE

P

ADS FROM THE

L

OAD

: About Stand-By

Mode to follow); such an attempt could result in a load release and possible injury to the

operator.

9

Certain load materials are too rough or porous to allow the lifter to form a seal which can be maintained for 5 minutes without

power. However, in geographical locations where CE Standards do not apply, it may be possible to use the lifter to lift such loads.
Contact Wood’s Powr-Grip for more information.

Advertising