Maintenance, Nspection, Chedule – Wood’s Powr-Grip FLEX5HV11DC User Manual

Page 15

Advertising
background image

Rev 11.0/8-12

13

FLEX-HV11DC: #35034

MAINTENANCE

WARNING: Always make sure battery is disconnected before servicing lifter.

I

NSPECTION

S

CHEDULE

Perform inspections routinely, according to the following frequency schedule:

Every-Lift Inspection

• Examine the vacuum pads and load surface for contamination or debris (see V

ACUUM

P

AD

M

AINTENANCE

to follow).

• Examine the vacuum pads, controls and indicators for visual damage (see V

ACUUM

P

AD

M

AINTENANCE

to follow).

• Test the battery for adequate charge (see B

ATTERY

T

EST

to follow).

If a battery’s charge appears to be inadequate, charge and retest the battery (see B

ATTERY

R

ECHARGE

to follow). If any other deficiency is detected during the inspection, correct it before

using the lifter and perform the Frequent Inspection to follow.

Frequent Inspection

(

following every 20-40 hours’ use; or whenever lifter is out of service for 1 month or more

)

• Examine the lifter’s structure for visual damage.
• Examine the vacuum system (including vacuum pads, fittings and hoses) for visual damage.
• Examine the air filter for conditions requiring service (see A

IR

F

ILTER

M

AINTENANCE

to follow).

• Perform the V

ACUUM

T

EST

to follow.

• Check for unusual vibrations or noises while operating the lifter.
If any deficiency is detected during the inspection, correct it before using the lifter and perform

the Periodic Inspection to follow.

Periodic Inspection

(

following every 250-500 hours’ use; or whenever lifter is out of service for 1 year or more

)

• Examine the entire lifter for external evidence of looseness, excessive wear, deformation,

cracks, excessive corrosion, dents to structural or functional components, cuts, or any
deficiency which might constitute a hazard.

• Inspect all parts of the electrical system for damage, wear or contamination that could

constitute a hazard, in compliance with all local codes and regulatory standards that are

relevant for the geographical region.

CAUTION: Be sure to use appropriate cleaning methods for each type of electrical

component, as specified by codes and standards. Improper cleaning

can damage components.

• Keep a written record of all Periodic Inspections.

Advertising