Specifications – Wood’s Powr-Grip VLGG1011LAC User Manual

Page 5

Advertising
background image

Rev 22.0/9-13

3

VLGG-AC: #35163

SPECIFICATIONS

Description:

Designed for use with a crane or other hoisting equipment, the VLGG10-AC

lifters employ vacuum to hold a load for lifting in the upright orientation.

Model Number:

VLGG109AC

VLGG1011LAC

Vacuum Pads: (standard rubber, spring-mounted for ¼" [7 mm] travel, with #60 filter screen)

Ten 9" [23 cm] nominal

diameter (Model VPFS9)

Ten 11" [28 cm] nominal

diameter, lipped (Model G3370)

Maximum Pad Spread:

51¼" x 117½"

53¾" x 120"

(to outer edges)

[1302 x 2985 mm]

[1365 x 3048 mm]

Lifter Weight:

197 lbs [90 kg]

203 lbs [92 kg]

Load Capacity:

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad:

120 lbs [54.5 kg]

180 lbs [81.5 kg]

Maximum:

1200 lbs [545 kg]

1800 lbs [815 kg]

Power Source:

See serial number plate for specific AC voltage, frequency and amperage.

Vacuum Pump:

Rotary vane type, 4 SCFM [113 liters/minute] nominal airflow

or

Diaphragm type, 3 SCFM [85 liters/minute] nominal airflow

Vacuum Reserve Tank:

Vacuum reservoir helps prevent immediate vacuum loss in case of power

failure.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and

negative kPa.

Vacuum Lift Lights:

Green lights are energized whenever vacuum level is sufficient for lifting

maximum load weight (higher than 16" [-54 kPa]).

Options:

See separate instructions about optional features.

Operating Elevation:

Maximum = 10,000 feet [3048 meters]

Operating Temperatures: 32° to 100° F [0° to 38° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles,

when used and maintained as intended. Vacuum pads, filter elements and

other wear-out items are excluded; see MAINTENANCE and REPLACEMENT

PARTS LIST for more information. For the D

ISPOSAL OF THE

L

IFTER

after its

service life, see INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS manual only when requirements of a CE Standard are different from

requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.

Advertising