Wood’s Powr-Grip EO3VLW User Manual

Page 9

Advertising
background image

Rev 9.0/9-13

7

EO3VLW: #35193AFT

T

ESTING

S

CHEDULE

Perform these tests when installing the Vacuum Loss Warning Buzzer

initially

and

each time

following a repair or modification

. Correct any deficiency and retest before using the Warning

Buzzer.
• Perform a vacuum leak test as directed in the lifter's instruction manual.
• Test all features and functions of the Warning Buzzer (see OPERATING FEATURES, OPERATION

and MAINTENANCE).


Note: See MAINTENANCE topics to follow for additional directions about inspecting and testing

specific Warning Buzzer components.

M

AINTENANCE

S

CHEDULE

Although the Vacuum Loss Warning Buzzer does not require maintenance on a routine basis,

maintenance must be performed whenever a deficiency is indicated by routine inspections or

tests. Any maintenance warranted must be performed before resuming normal use of the
Warning Buzzer.

B

ATTERY

T

EST AND

R

EPLACEMENT

The Vacuum Loss Warning Buzzer is designed so its battery can be tested while the lifter is not

running or attached to a load: Press the battery test button and observe the color of the battery
indicator light (note that the buzzer sounds, also, if the button is held more than a few seconds).
A

green

light indicates that the battery is in good condition, whereas a

red

light indicates that the

battery does not have sufficient energy to power the Warning Buzzer. If a red light is showing,
replace the battery, as follows:
1) Insert a coin or screwdriver in the slot at the bottom of the battery holder and press inward.
2) While continuing to press in, press up on the battery holder. The battery tray should slide out

easily.

3) Remove the battery from the tray.
4) Install a new 9-volt battery, matching the polarity marked on the battery with the polarity

marked on the tray.

5) Slide the battery tray into the battery holder until the tray snaps into place.
6) Retest the Warning Buzzer.