Pfc configuration example – Blade ICE RACKSWITCH G8124-E User Manual

Page 202

Advertising
background image

BLADEOS 6.5.2 Application Guide

202 Chapter 14: FCoE and CEE

BMD00220, October 2010

PFC Configuration Example

Note –

DCBX may be configured to permit sharing or learning PFC configuration with or from

external devices. This example assumes that PFC configuration is being performed manually. See

“Data Center Bridging Capability Exchange” on page 211

for more information on DCBX.

This example is consistent with the network shown in

Figure 22 on page 189

. In this example, the

following topology is used.

In this example, PFC is to facilitate lossless traffic handling for FCoE (priority value 3) and a
business-critical LAN application (priority value 4).

Assuming that CEE is off (the G8124 default), the example topology shown in

Table 18

can be

configured using the following commands:

1.

Turn CEE on.

Note –

Turning CEE on will automatically change some 802.1p QoS and 802.3x standard flow

control settings and menus (see

“Turning CEE On or Off” on page 192

).

Table 18

Port-Based PFC Configuration

Switch

Port

802.1p

Priority

Usage

PFC

Setting

1

0-2

LAN

Disabled

4

Business-critical LAN

Enabled

others

(not used)

Disabled

2

3

FCoE (to FCF bridge)

Enabled

others

(not used)

Disabled

3

3

FCoE

Enabled

others

(not used)

Disabled

4

0-2

LAN

Disabled

4

Business-critical LAN

Enabled

others

(not used)

Disabled

RS G8124(config)# cee enable