Beckett R7184 User Manual

Technical information bulletin, Benefits

Advertising
background image

NEW FEATURES IN THE BECKETT R7184 SERIES 5

PRIMARY CONTROLS

Advances in electronics technology are making an exciting impact in our oilheat industry. These developments
have enabled control manufacturers to put high-performance features into residential primary controls.
Since its introduction in 1999, the Beckett R7184 primary control has made advancements and added
features to meet the need of a changing industry. This technical bulletin will discuss some of the new
benefits and wiring improvements to the Beckett R7184 revision 5 primary control.

The operational sequence, interrupted
ignition, limited recycle and reset,
diagnostic LED and communication
port remain consistent on the R7184A,
B, P revision 5 as with the previous
revision.

BENEFITS

•

Matching wire colors between components and control will
reduce mistakes during wiring.

•

Quick Connects on the lead wires from the burner components
and wire harnesses allow quick component change-out and
reduce the number of leads in the wiring box.

•

Data port connection enables reading control characteristics
with Honeywell Diagnostick

™

, QS7100T tester or OnWatch

QuickRead

™

711.

•

EnviraC

OM

™

communication terminals have been added for

future networking customization for HVAC systems.

TECHNICAL INFORMATION BULLETIN

APRIL 2004

How to tell the revision level:

The Revision numbers 1, 2 and 3
are located on the label designated
by the number printed on its side.

Revisions 4 and 5 have been
relocated to the side of the primary
control cover. The number also
is

printed on its side.

BECKETT R7184 PRIMARY CONTROL

Series 4

Series 5

Data port

Alarm contacts

EnviraC

OM

™

(3) terminals

or

T-T
(2) terminals

Blue

Violet

Orange

Black

Red

New and relocated features

Component color code

Igniter

Valve

Motor

Line

Limit

Series 5 Control: