www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80016-R Rev 5/08

*Nipple not included

**Optional setting, contact factory

***Weight does not include burner and controls

T&P Valve: Factory Installed

Drain Valve: Factory Installed Brass Valve

Standard Voltage (all): 120V, 60 Hz, 1P

Pressures (all): Working Pressure, 150 psi; Testing Pressure, 300 psi

ASHRAE: All Bock Products Meet or Exceed Current ASHRAE Standards.

Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local

codes, refer to NFPA 54 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F. Bock recommends a tempering valve or

anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

32PG, 50PG-ES, 51PG, 71PG

33PG, 40PG

120PG

This product is available from:

PowerGas

Outlet

Auxiliary

Outlet:

32PG-EC/BCS,

71PG-EC,

51PG-EC/BCS

Inlet

T&P

Relief

Valve

D

C

B

E

A

Drain

Valve/

Return:

32PG,

50PG-ES,

51PG

Aquastat

Connection

Drain

Valve/

Return:

71PG

Hand-Hole:

50PG-ES

Hand-Hole:

71PG

Outlet

Auxiliary

Outlet:

40BCSE

T&P

Relief

Valve

C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Inlet

Outlet

Auxiliary

Outlet

Inlet

T&P

Relief

Valve

D

C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Hand-Hole

Return

Model Storage

(gal)

Rated

Input

Recovery

@ ∆ 90°F

(GPH)

Max. Temp

Setting

(°F)

Inlet

Pipe

Dia.

Outlet

Pipe

Dia.

Return

Pipe

Dia.

Dimensions

Shipping Weight

(lbs)***

BTUH

A

B

C

D

E

Standard

ASME

32PG

32

104,000

110

160

3/4”

3/4”

3/4”

51”

20”

6”

11”

17”

312

N/A

33PG

33

104,000

109

160

3/4”

3/4”

3/4”

43 1/4”

24”

6”

N/A

17 1/4”

318

N/A

40PG

40

126,000

134

160

3/4”

3/4”

1”

61”

20”

6”

N/A

18”

341

N/A

50PG-ES

50

140,000

142

160**

1”

1 1/2”*

1 1/2”

52”

26”

6”

13 1/2” 18 1/2”

409

N/A

51PG

50

152,000

159

160**

1”

1”

3/4”

59”

24”

6”

11”

18”

370

N/A

71PG

68

173,000

170

160**

1”

1 1/2”*

1 1/2”

66”

26”

6”

13 1/2”

22”

478

N/A

120PG

113

155,000

160

180

1”

2”*

2”

67”

31 1/2”

6”

19”

22”

749

N/A

No field conversion kits available.