C. TROUBLESHOOTING

C.1 Error codes

Overview

The following table gives an overview of some important error codes displayed on the LED display of the projector.

Error code

Description

Caused by

Action

2002

lamp start failed

•

hot restrike

•

lamp with many strikes

•

maximum run time exceeded

•

Let cool down the lamp for at
least 3 minutes.

•

Replace the lamp with a new
one

6000

tilt switch

tilt angle is out of specifications

•

Correct projection installation.

•

Change the tilting so that the
tilt angle becomes within the
specifications..

5002

ambient overtemperature

ambient temperature sensed by
the projector is above 45°C

Cool down the installation
environment.

1100

Lamp overtemperature

lamp to hot

Let cool down the lamp

3004

Top fan error

fan is not turning

failure

Call a qualified service engineer

3005

Anode fan error

fan is not turning

failure

Call a qualified service engineer

3006

Cathode fan error

fan is not turning

failure

Call a qualified service engineer

2000

No LPS detected

no communication with lamp power
supply

Call a qualified service engineer

2506

Lamp ignition failed

•

hot restrike

•

lamp with many strikes

•

maximum run time exceeded

•

Let cool down the lamp for at
least 3 minutes.

•

Replace the lamp with a new
one

If problem persists, call a qualified
service engineer

5001

DMD temperature

•

temperature of one or more
DMD’s is too high

•

temperature of one or more
DMD’s is too low

Let cool down the projector. If it
persists, call a qualified service
engineer

1102

Lamp insertion not OK

•

Lamp not fully inserted

•

Screws not fully tightened

•

Check the lamp insertion

•

Tighten the screws

4004

SMPS EEPROM corrupt

•

no EEPROM on SMPS

•

Wrong programmed
EEPROM on SMPS

Download correct software

4108

Group Fan 1 voltage too low

Call a qualified service engineer

4109

Group Fan 2 voltage too low

Call a qualified service engineer

4110

Group Fan 3 voltage too low

Call a qualified service engineer

R5976801 SLM R9+ 20/10/2004