General Messages

Most messages and alerts will appear at the bottom of the normally used screens.
Several alerts and messages may be displayed in a sequence.

Some messages can be reset from the panel. Messages that can be reset
will appear with a “right arrow” at the end of the message. This message
can be selected by navigating to it at pressing the Select button.

The water is too hot – M029

The system has detected a spa water temp of 110°F (43.3°C) or more, and spa functions are disabled. System will auto
reset when the spa water temp is below 108°F (42.2°C). Check for extended pump operation or
high ambient temp.

* This message can be reset from the topside panel.

Possible freezing condition

A potential freeze condition has been detected, or the Aux Freeze Switch has closed. All water devices are activated.

In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.

This is an operational message, not an error indication.

– – –°F

– – –°C

Water Temperature is Unknown

After the pump has been running for 1 minute, the temperature will be displayed.

Clean the filter

`

M0XX numbers are Message Codes. See Page 13.